Block heater orientation

Forum Forums Tractor Modifications Block heater orientation

Viewing 4 reply threads
  • Author
    Posts
    • #50476
      DemocracyNow
      Participant
        • Offline

        Having gone through several engine block heaters on my Farm Pro 254 in the last 20 years I have seen a pattern.
        The copper connectors molded into the silicon? molded electrical cord connections corrode and loosen and then fail.
        Extreme heat is the problem.
        To Ameliorate the problem I have flipped the position of the block heater so that the generated heat accumulates in the aluminum body of the heater and the copper cord connections are at the bottom of the heater and not on top. I simply loosened the two hose clamps and rotated the body of the heater.
        It appears  that this has also quickened the warmup because the heat can readily rise into the engine block water jacket.

      • #50477
        DavidPrivett
        Participant
          • Offline

          makes sense heat rises make it travel further in the fluid and make a more effecient transfer of temps. But I have not had this issue with the cord,, is the block heater you use in the block or is it the in line type placed in the lower radiator hose?

        • #50478
          DemocracyNow
          Participant
            • Offline

            David;Great observation and thanks.
            I was wrong to call it a “block heater”.

            I was referring to a lower radiator hose heater and the silicone rubber cap that holds the 4 copper contacts for temperature switch and immersion heater. When that silicone cap is oriented to the top of that lower radiator hose it degrades from heat and always fails first.
            Rotate the heater 180 degrees to reduce or eliminate the problem.

          • #50479
            DemocracyNow
            Participant
              • Offline

              Here is the reoriented lower hose heater.
              This one has been modified because the factory silicone rubber cap and contacts overheated and had to be discarded.

              Attachments:
              You must be logged in to view attached files.
            • #50481
              DavidPrivett
              Participant
                • Offline

                I to have a lower hose heater on my dong feng le204a , I will take a closer look at mine as I have not had any trouble with it, but I only used it once this past winter. I put mine on a 10 amp appilance timer and have it kick on a coupla hours before I want to use the tractor. I guess that also would minimize a over heating issue.

                • #50482
                  DemocracyNow
                  Participant
                    • Offline

                    David;The heat generation will deteriorate those copper connections and silicone cap.
                    I have had three fail in 22 years. All from excess heat.
                    If your electrics are in the upper orientation simply loosen the hose clamps and spin it.
                    All that heat will go into the block and not the electrics.

              Viewing 4 reply threads
              • You must be logged in to reply to this topic.